Silicone Cables up to 180°C: how to choose | Caviterm

Silicone cables: characteristics, limitations and when to use them

October 29, 2026

Silicone cables are electrical cables with extruded silicone rubber insulation, designed for continuous operation from -40 to +180°C while remaining flexible at both high and low temperatures. They are a common choice for wiring machinery, heating elements and household appliances when PVC and other rubber compounds can no longer withstand the heat. However, they have a specific limitation: above 180–200°C, a different insulating material is required.

This guide explains how to read a silicone cable datasheet, the differences between standard, braided, armoured and shielded versions, and what to check before placing an order.

Silicone cables: what they are and their temperature limits

A silicone cable features extruded silicone rubber insulation and, in multicore versions, a silicone rubber outer sheath. In Caviterm datasheets, the material is specified as EI2-type silicone according to CEI EN 50363, the standard defining insulating and sheathing materials for low-voltage power cables.

The operating temperature range is -40 to +180°C. By comparison, a standard PVC cable is rated up to 70°C, while special PVC versions can reach 105°C.

For Caviterm, silicone insulation is the starting point for high-temperature cables, particularly when supplying power to electrical heating elements.

Compared with insulating materials designed to withstand even higher temperatures, silicone offers a practical advantage: it remains soft and flexible, takes up minimal space and is easy to install, unlike other, more complex insulation materials.

How to read a silicone cable datasheet

Silicone cable datasheets generally contain the same technical specifications. Understanding them helps prevent mistakes caused by selecting a cable based solely on its maximum temperature rating.

Datasheet specification What it indicates Value in the Caviterm silicone cable range
Conductor Material and conductor construction Bare, tinned or nickel-plated copper, or nickel; flexible class 5 according to IEC 60228
Insulation Insulating material surrounding each individual conductor EI2-type silicone, CEI EN 50363
Outer sheath External covering of multicore cables EI2-type silicone
Braiding, armour, shielding Additional protection over the silicone Electrical-grade fibreglass, polyester, galvanised steel, tinned copper, AISI 304 stainless steel
Operating temperature Continuous operating range -40 to +180°C
Rated voltage Voltage to earth and between conductors 300/500 V, up to 10 kV for high-voltage versions
Test voltage Insulation testing 1,000 V AC for 1 minute
Bending radius Minimum permissible bending radius 4 to 10 times the cable diameter
Fire performance Applicable standard Flame-retardant according to IEC 60332-1

Class 5 indicates a flexible conductor made of fine wires, which is the standard construction across the range. The GS 180°C single-core cable can also feature a rigid class 1 conductor and, in addition to bare or tinned copper, nickel-plated copper or nickel.

The minimum bending radius increases when additional protective layers are present: it is 4 times the cable diameter for standard silicone cables, 6 times for the GSMA armoured multicore cable and 10 times for the shielded version.

This is an important specification to check when cables need to be installed in confined spaces.

Standard, braided, armoured and/or shielded silicone cables

All versions use the same EI2 silicone insulation. What changes is the outer covering.

The table below summarises the construction of Caviterm’s 180°C silicone cable range.

Version Construction Typical application
Single-core (GS) Conductor with silicone insulation Internal wiring of machinery and equipment
Multicore (GSM) Twisted insulated conductors with silicone outer sheath Power supply connections requiring multiple conductors
Fibreglass braided (GSV) Silicone insulation with impregnated fibreglass braid Additional textile covering over the silicone
Polyester braided (GSP) Silicone insulation with impregnated polyester braid Additional textile covering over the silicone
Armoured (GSMA) Multicore cable with galvanised steel braid Protection against impacts, abrasion and crushing
Shielded (FG4OH2G4) Multicore cable with tinned copper braid Protection against electromagnetic interference

In the GSM 180°C multicore cable, the insulated conductors are twisted together, with fillers added where necessary to give the cable a circular cross-section.

Conductor colours follow a defined pattern: brown and blue for two-core cables, with a green/yellow protective conductor from three cores upwards, and numbered black conductors for cables with more than six cores.

Fibreglass or polyester braid

The braid is an impregnated textile covering that surrounds the silicone insulation.

In the GSV 180°C cable, it consists of impregnated electrical-grade fibreglass. In addition to protecting the silicone, this material improves the cable’s thermal resistance.

The maximum temperature rating remains unchanged, but the additional protection helps extend the cable’s service life.

The GSP 180°C cable, on the other hand, uses an impregnated polyester braid, which significantly improves mechanical resistance, particularly against rubbing and abrasion.

Armour and shielding: two different types of protection

Armour and shielding are often confused, but they serve very different purposes.

Metal armour protects the cable against impacts, abrasion and crushing. In the GSMA 180°C armoured cable, it consists of a galvanised or stainless steel braid applied over the silicone sheath, increasing the minimum bending radius to 6 times the cable diameter.

Shielding, on the other hand, protects signals and nearby equipment against electromagnetic and/or electrostatic interference.

In the FG4OH2G4 180°C shielded cable, the shield consists of a tinned copper wire braid with a minimum coverage of 80%, positioned beneath a brick-red silicone outer sheath.

The limitations of silicone: when another insulating material is needed

The first limitation is temperature.

If the application is expected to exceed 180°C, silicone deteriorates very rapidly and a different insulating material is therefore required: PTFE up to 260°C, impregnated fibreglass from 320 to 400°C, and mica and special fibreglass up to 500–600°C.

A full comparison is available in our guide to high-temperature cable insulation materials.

The temperature to consider is the actual cable temperature, not the ambient temperature. Near ovens and heating elements, radiant heat can cause the cable to reach a higher temperature than the surrounding air.

It is therefore essential to measure the actual temperature at the hottest point.

The second limitation concerns mechanical stress. Where the cable is exposed to impacts or crushing, insulation alone is not enough and an armoured version is required.

The third limitation involves aggressive environments. Compatibility with oils, solvents and other chemicals depends on the specific compound and substance involved. It should be checked case by case with the manufacturer’s technical department before ordering.

Where silicone cables are used

Silicone electrical cables are suitable for applications involving moderate heat where installation flexibility is important.

Common applications include:

  • Wiring for machinery operating near heat sources, such as plastic and rubber extrusion and injection moulding lines;

  • Connections to heating elements and heaters;

  • Household appliances and hobs;

  • Packaging machinery with heated components.

For higher-voltage circuits, the range also includes dedicated GS1 and GSV1 versions, with rated voltages up to 10 kV for 1 mm² conductor cross-sections.

How to choose a high-temperature silicone cable

Before ordering a high-temperature silicone cable, these five checks can help avoid the most common mistakes.

  1. Measure the temperature at the hottest point: if it remains within 180°C, silicone is suitable. If it exceeds this threshold, another insulating material is required.

  2. Determine the number of cores and size the conductor cross-section: choose single-core cables for internal wiring and multicore cables when several conductors need to be grouped into one cable.

  3. Assess mechanical risks: if the cable may be exposed to impacts or crushing, choose an armoured version.

  4. Check for electrical interference: near inverters, motors or signal lines, consider a shielded cable. Further selection criteria are explained in our guide on when to shield an electrical cable.

  5. Analyse installation space and voltage requirements: check that the minimum bending radius is compatible with the cable ducts and that the rated voltage matches the electrical circuit.

Caviterm: silicone cables up to 180°C

Caviterm manufactures high-temperature cables in Provaglio d’Iseo, in the province of Brescia, Italy, under an ISO 9001:2015-certified quality management system.

Within its high-temperature electrical cable range, silicone covers operating temperatures up to 180°C, with single-core, multicore, braided, armoured and shielded versions, as well as dedicated high-voltage models.

Complete technical datasheets for each cable are available for download from the website’s restricted area.

If your application requires a particular configuration in terms of conductor cross-section, number of cores or protective coverings, you can contact our sales department and work with our technical team to identify a customised solution.

Faq

What is the maximum temperature a silicone cable can withstand?

A silicone cable can operate continuously at temperatures up to 180°C, with a lower operating limit of -40°C. Above 180°C, different insulating materials are required, such as PTFE, impregnated fibreglass or mica.

What is the difference between silicone and PVC cables?

Standard PVC cables are rated up to 70°C, while special PVC versions can reach 105°C. Silicone cables, by comparison, can withstand temperatures up to 180–200°C.

Silicone also remains flexible at low temperatures, whereas PVC tends to become stiffer.

What does EI2 insulation mean?

EI2 is the designation used by the CEI EN 50363 standard for the silicone rubber compound used to insulate power cables.

On a technical datasheet, it indicates that the insulation is made from silicone complying with the standard.

.

Are silicone cables flame-retardant?

Yes, provided this is stated in the datasheet.

Caviterm silicone cables are flame-retardant according to IEC 60332-1, the test standard used to assess flame propagation on a single vertically mounted cable.

When is an armoured silicone cable necessary?

An armoured silicone cable is needed when it is exposed to impacts, abrasion or crushing, for example along machinery with moving parts or through unprotected cable routes.

The armour consists of an external metal braid and should not be confused with shielding, which provides protection against electromagnetic interference.